PortaCount Pro+ 8038

Overview

No other fit tester can quantitatively fit test ALL types of respirators - gas masks, SCBAs, respirators, even N95 disposable (filtering-facepiece) respirators. The PortaCount Pro+ Respirator Fit Tester eliminates the guesswork associated with tedious and error-prone qualitative fit test methods.

If the mask requires fit testing, count on the PortaCount Pro+ fit tester to provide the fastest, easiest and best OSHA-accepted fit test method.

Features & Benefits

  • Fit test ANY tight-fitting respirator including N95, P2 and P1 disposables
  • Faster N95 fit testing time -- down from 11:30 seconds to 7:15 seconds
  • Greater simplicity with the built-in N95 Companion™ technology
  • Stand alone operation
  • Or use with external computer to generate reports and print fit test cards
  • Reduced need for an external particle generator
  • Able to perform N95 fit testing with much lower ambient particle concentrations
  • Color touch screen
  • OSHA-compliant for all respirators, including N95
  • Measures fit factors greater than 10,000
  • Switch between different respirator types in under a minute
  • Automates fit testing with FitPro™ Fit Test Software
  • Optional Card Printer allows you to print individual fit test cards

Applications

  • Quantitave respirator fit testing (QNFT)
  • Disposable filtering-facepiece fit testing for Series 100, 99, P3 and HEPA masks
  • Half mask fit testing
  • Full-face mask fit testing
  • Gas mask fit testing
  • PAPR mask fit testing
  • SCBA mask fit testing

Technical Specifications

Product Specifications Description
Fit Factor Range 1 to greater than 10,000, 1 to 200 for N95 masks
Typical Fit Factor Accuracy ±10% of reading
Respirator Facepieces that can be Fit Tested Full-face elastomeric
Half-face elastomeric
NIOSH series-100 filtering-facepiece
NIOSH series-99 filtering-facepiece
NIOSH series-95 filtering-facepiece
Fit Factor Measurement Direct measurement of fit factor (Cout/Cin)
Dimensions 6.75 in. x 8.5 in. x 9.5 in. (17 cm x 22 cm x 24 cm)
Weight Unit Only: 6.8 lb (3.1 kg)
With Standard Accessories and Case: 18 lb. (8.2 kg)
Power Autosensing 100 to 250 VAC, 50 to 60 Hz
Flow Rate Sample: 350 cm3/min
Total: 1000 cm3/min (nominal)
Temperature Range Operation: 32 to 100°F (0 to 35°C)
Storage: -40 to 160°F (-40 to 70°C)
Alcohol Hours Per Charge: 6 hours at 70°F (21°C)
Alcohol Type: 99.5%+ reagent grade isopropyl
Carrying Case Dimensions (HWD): (23 cm x 36 cm x 53 cm)
Pass/Fail Setting User-selectable: 0 to 10,000
Factory Recalibration Interval One year
Warranty Two years on workmanship and materials
Minimum PC Hardware Requirements for FITPRO Fit Test Software Microsoft® Windows® XP and Windows Vista® software
Optional Accessories Model 8901 Fit Test card printer
Mask Sampling Adapters for select respirator models

ECO Environmental now offers the Inspectra Laser methane gas detector for hire. The Inspectra Laser is a methane-specific monitoring device which is ATEX rated and can detect from as low as 1ppm.More...