The Toxi pro single gas detector offers value for money without compromising on quality.This light weight Gas meter is fully serviceable, reusable, with real-time, peak, STEL, and TWA readings, as well as a 20-incident event logger and black box recorder.
The latest models come standard with datalogger and vibrating alarm. The ToxiPro is highly recommended for use with the ToxiPro IQ Epress Docking Station, which also doubles as an automated bump test and calibration station.
Available Sensors
O2, CO, CO+, H2S, SO2, CO-H, Cl2, ClO2, NH3, NO2, PH3, HCN
Features & Benefits
- Compact & rugged
- IPX5/IPX7 rated protection against water ingress
- Over-molded boot
- One button operation
- Large display
- Loud alarm
- Top & front mounted bright LED
- Automatic event logger (20 events, including sensor type, max, average, time and duration)
- IrDA® PC communication
- Comes standard with black-box recorder
- Replaceable lithium – 9000 hrs of operation
- Current, max, STEL and TWA gas readings, Time Low, high, STEL and TWA audible visual vibrating alarm
Applications
- Refineries
- Oil production
- Contractors
- Turnarounds
- Scheduled plant maintenance
- Chemical plants
- Fire service
- Industrial safety
- Pulp mills
- Heavy industry
- Agriculture
Technical Specifications
| Product Specification | Description |
| Instrument Type | Replaceable battery and sensor |
| Dimensions | 8.4 x 5.5 x 2.9 cm (3.3 x 2.2 x 1.2 in.) |
| Weight | 110 g (3.9 oz) |
| Alarms | Two factory-set alarm levels, plus STEL and TWA. (Can be changed with optional BioTrak software) |
| Audible Alarm | Loud warbling two-tone alarm rated at 92 dBA |
| Display Backlight | Activates with button |
| Controls | One button operation, including calibration |
| Battery Life | Up to 9000 hrs. (Approximately 1 year) |
| Housing | Clear polycarbonate with thermal-plastic elastic (TPE) overmold |
| IP Rating | Meets IPX5 / IPX7 water rating |
| Intrinsic Safety | c-UL-u Classified for Class I, Division 1, Div 1, Group A, B, C, D T4 |
| UL Classified for Class II, Div 1, Group E, F, G | |
| Event Logger | 20 Events, includes start time, end time, duration, peak and average readings |
| Datalogging | Approx. 120 hrs @ 1 min. interval (Interval can be changed with optional BioTrak software, IrDA required) |
| Standard Accessories | Calibration adapter, hose, operators guide and quick reference card |
| Readouts | Real-time, peak, STEL, TWA and time of day readings |
Downloads