PortaCount Pro+ 8038
PortaCount Pro+ 8038
Overview

No other fit tester can quantitatively fit test ALL types of respirators – gas masks, SCBAs, respirators, even N95 disposable (filtering-facepiece) respirators. The PortaCount Pro+ Respirator Fit Tester eliminates the guesswork associated with tedious and error-prone qualitative fit test methods.
If the mask requires fit testing, count on the PortaCount Pro+ fit tester to provide the fastest, easiest and best OSHA-accepted fit test method.
Features & Benefits
- Fit test ANY tight-fitting respirator including N95, P2 and P1 disposables
- Faster N95 fit testing time — down from 11:30 seconds to 7:15 seconds
- Greater simplicity with the built-in N95 Companion™ technology
- Stand alone operation
- Or use with external computer to generate reports and print fit test cards
- Reduced need for an external particle generator
- Able to perform N95 fit testing with much lower ambient particle concentrations
- Color touch screen
- OSHA-compliant for all respirators, including N95
- Measures fit factors greater than 10,000
- Switch between different respirator types in under a minute
- Automates fit testing with FitPro™ Fit Test Software
- Optional Card Printer allows you to print individual fit test cards
Applications
- Quantitave respirator fit testing (QNFT)
- Disposable filtering-facepiece fit testing for Series 100, 99, P3 and HEPA masks
- Half mask fit testing
- Full-face mask fit testing
- Gas mask fit testing
- PAPR mask fit testing
- SCBA mask fit testing
Technical Specifications
| Product Specification | Description |
| Fit Factor Range | 1 to greater than 10,000, 1 to 200 for N95 masks |
| Typical Fit Factor Accuracy | ±10% of reading |
| Respirator Facepieces that can be Fit Tested | Full-face elastomeric Half-face elastomeric NIOSH series-100 filtering-facepiece NIOSH series-99 filtering-facepiece NIOSH series-95 filtering-facepiece |
| Fit Factor Measurement | Direct measurement of fit factor (Cout/Cin) |
| Dimensions | 6.75 in. x 8.5 in. x 9.5 in. (17 cm x 22 cm x 24 cm) |
| Weight | Unit Only: 6.8 lb (3.1 kg) With Standard Accessories and Case: 18 lb. (8.2 kg) |
| Power | Autosensing 100 to 250 VAC, 50 to 60 Hz |
| Flow Rate | Sample: 350 cm3/min Total: 1000 cm3/min (nominal) |
| Temperature Range | Operation: 32 to 100°F (0 to 35°C) Storage: -40 to 160°F (-40 to 70°C) |
| Alcohol | Hours Per Charge: 6 hours at 70°F (21°C) Alcohol Type: 99.5%+ reagent grade isopropyl |
| Carrying Case | Dimensions (HWD): (23 cm x 36 cm x 53 cm) |
| Pass/Fail Setting | User-selectable: 0 to 10,000 |
| Factory Recalibration Interval | One year |
| Warranty | Two years on workmanship and materials |
| Minimum PC Hardware Requirements for FITPRO Fit Test Software | Microsoft® Windows® XP and Windows Vista® software |
| Optional Accessories | Model 8901 Fit Test card printer Mask Sampling Adapters for select respirator models |
Downloads
- PortaCount Pro+ : Product Brochure (594 KB)
- Portacount Pro+ : User Manual (866 KB)